    For safety, the BS1363 (UK, type G) is by far the best.

    • It’s fused. (Seriously why the hell aren’t all plugs fused!)

    • Live and neutral can’t be reversed.

    • Holes are gated (so no kids sticking spoons in).

    • High capacity, 240V at 13A gives 3kW of power.

    It’s only real downside is its size.

    • umfk@lemmy.world
      link
      fedilink
      arrow-up
      33
      arrow-down
      2
      ·
      18 hours ago

      Fusing plugs is completely unnecessary. The only reason this is done in the UK is because of old janky circuits only used in the UK.

      • pulsewidth@lemmy.world
        link
        fedilink
        arrow-up
        2
        ·
        edit-2
        5 hours ago

        Wrong, it’s fused because in the UK they have 32A 240V circuits, a fuse is important when dealing with that much current. In Australia we only have 16A 240V circuits as standard so there is no need for a fuse.

        • umfk@lemmy.world
          link
          fedilink
          arrow-up
          1
          ·
          3 hours ago

          They have fuses because of their ring circuits from after WW2. You’re the one who’s wrong.

    • fullsquare@awful.systems
      link
      fedilink
      arrow-up
      24
      ·
      18 hours ago

      Type E/F carries 16A/230V, and nowadays there are shutters included which only allow two pins to be inserted at once, not one but not the other. There’s no standard as of which pin should be L1 and neutral anyway, nor it should matter, and fuses in british plugs are to accommodate ring circuits, which were introduced as a result of copper shortages (ie decades of tech debt)

    • Treczoks@lemmy.world
      link
      fedilink
      arrow-up
      7
      arrow-down
      3
      ·
      15 hours ago

      Using fuses on outlets is fake security. You can put two 10A devices on a circuit, and the fuses won’t help. What’s important is that you have fuses for each line.

      All socket holes here are gated, too (Type F), but I have to admit there are grandfathered ones without gates in older installations. And we have 16A @ 240V.

      I have to admit that the idea of switches in each outlet is in principle a good one, but it makes the outlet way larger than other types, and adds extra complications that can break (yes, I had to fight with one like this in the UK).

      • cynar@lemmy.world
        link
        fedilink
        English
        arrow-up
        10
        ·
        15 hours ago

        The fuses aren’t to protect the circuit, they protect the end and intermediate devices. The breakers protect the actual circuit.

        E.g. you’ve got a thin flex for a low power lamp. You don’t have to worry about a short allowing 40A to flow down a 2A cable.

        • Treczoks@lemmy.world
          link
          fedilink
          arrow-up
          5
          arrow-down
          3
          ·
          15 hours ago

          How many cheap import lamps do have an appropriate fuse?

          And the short circuit 40A is better covered by a fast-acting breaker.