People who joke about legos haven’t stepped on this bad boy

  • Devial@discuss.online
    link
    fedilink
    English
    arrow-up
    64
    arrow-down
    2
    ·
    4 hours ago

    Best plug+receptor design in the world for electrical safety.

    Worst plug design in the world for bottom of foot safety.

    • Horsecook@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      17
      arrow-down
      8
      ·
      3 hours ago

      Best plug+receptor design in the world for electrical safety.

      That’s debatable. The plug safety features only exist because of the UK’s uniquely substandard wiring.

      • Devial@discuss.online
        link
        fedilink
        English
        arrow-up
        15
        arrow-down
        1
        ·
        edit-2
        21 minutes ago

        No it isn’t. It’s debatable if the safety features are still necessary with modern wiring and electric code imporovments, but the features are objectively there, and they objectively make the plugs safer.

        And the design of these features wasn’t because of “substandard” wiring. It is because the UK used to use ring circuits in old houses, which are unsuitable to be protected by central breaker boards with breakers for each room, necessitating fuses in the plugs. That doesn’t make the system any less safe. As long as a fuse is present, and the circuits are adequately sized, where precisely on the circuit a fuse is located is irrelevant.

        Also, the fuse inside the plug provides an utterly unique advantage that no other country has: The fuse can be used to protect the external wire from over current. Centralised fuses are exclusively designed to prevent over current on the main, internal circuit, they don’t give a crap what happens on the other side of an outlet. A central fuse protecting a 16A circuit will do nothing to stop you from pulling 15Amps through a 3 amp cable. A fuse inside the plug, appropriately sized for those 3 Amps, will in fact protect the cable itself. This is particularly useful for extension cords. Other countries without fused plugs need to either just flat out mandate ALL extension and multiplug cords be capable of safely handling the maximum current of a household circuit (e.g. Germany) OR just ignore that rather major safety hazard entirely and just kinda hope that nothing bad happens (e.g. USA) (if you’ve ever wondered, that’s specifically why chaining extension cords together in the US is considered dangerous)

    • WhatAmLemmy@lemmy.world
      link
      fedilink
      English
      arrow-up
      3
      ·
      3 hours ago

      Sounds like the problem is people leaving plugs lying on the ground? Otherwise known as user error.